M20AD Technical Specification
Scroll to bottom to see the Site Test Certificate.
See illustrations below to see how M20AD Soundproofing can improve the sound insulation of a stud partition.

| Properties Values | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Detail |
Nominal partition Thickness (mm) |
Approx weight (kg/m2) |
Fire Resistance (hours) | Expected sound loss with no infill (db) |
Min expected sound loss with AMW75 infill |
|||||||||
| 1 | 100 | 19kg/m2 | 1/2 | 30 | 34 | |||||||||
| 2 | 145 | 53kg/m2 | 1/2 | 40 | 45 | |||||||||
| 3 | 190 | 87kg/m2 | 1 | 42 | 47 | |||||||||
The estimated soundproofing performance of the stud partitions shown above are for partitions with no holes and all joints properly sealed. The sound insulation performance indicated may vary from site to site and should only be used as a guide.
The soundproofed wall shown in the detail below has an approx 87% reduction in sound transmission and complies with the requirements of the latest Building Regulations. It is therefore, ideal for insulating walls separating stairs and hallways where space is at a premium.
Please see the Test Certificate below